Botswana Laws

BUILDING CONTROL: SUBSIDIARY LEGISLATION

DumelaGaborone

CHAPTER 65:02 – BUILDING CONTROL: SUBSIDIARY LEGISLATION

INDEX TO SUBSIDIARY LEGISLATION

Building Control (Grade II Dwelling-Houses) (Appointment of Local Authorities) Order

Building Control (Grade II Dwelling-Houses) Regulations

Building Control Regulations

Establishment of Building Regulations Board Order

BUILDING CONTROL REGULATIONS

(under section 4)

(13th February, 1981)

ARRANGEMENT OF REGULATIONS

    REGULATION

PART I
Preliminary

    1.    Citation

    2.    Interpretation

PART II
Administration

    3.    Administration to be agreed between Building Authorities

    4.    Deemed-to-satisfy

    5.    Exempted buildings

    6.    Application

    7.    Designation of purpose groups

    8.    Change of use

    9.    Application for permit

    10.    Fees

    11.    Issue of permit

    12.    Rejection of permit

    13.    Title to land and planning approval

    14.    Notices of commencement and completion of certain stages of work

    15.    Inspection

    16.    Sampling of materials

    17.    Permit to occupy

    18.    Dangerous buildings

    19.    Water supply

    20.    Builder to comply with notice to demolish, etc.

    21.    Compliance with law

    22.    Appeals

PART III
Materials

    23.    Suitable materials

    24.    Special treatment of timber in certain areas

PART IV
Preparation of Site and Resistance to Moisture

    25.    Preparation of site

    26.    Protection of floors next to ground

    27.    Protection of walls against moisture

    28.    Materials below ground level

    29.    Weather resistance of external walls

    30.    Prevention of damp in cavity walls

    31.    Weather resistant walls

PART V
Structural Stability

    32.    Application of Part

    33.    Foundations

    34.    Structure above foundations

PART VI
Structural Fire Precautions

    35.    Determination of purpose group for purposes of this Part

    36.    Measurement

    37.    Provision of compartment walls and floors

    38.    Fire resistance

    39.    External walls

    40.    Requirements for compartment walls and floors

    41.    Protected shafts

    42.    Fire-resisting doors

    43.    Fire-stopping

    44.    Restriction on spread of flame over surface of wall or ceiling

    45.    Roofs

    46.    Provision of exits

    47.    Number of exits

    48.    Travel distance in relation to exits

    49.    Requirements as to exits

    50.    Width of exits

    51.    Enclosure of stairways

    52.    Construction of ramp

    53.    Doors in exits

    54.    Access to building for fire-fighting purposes

    55.    Provision of fire-mains

    56.    Occupant capacity

PART VII
Standards of Accommodation

    57.    Access

    58.    Stairs

    59.    Guarding of stairways

    60.    Guarding of landings, balconies and flat roofs

    61.    Accommodation

    62.    Size of habitable rooms

    63.    Height of room

    64.    Place for cooking

    65.    Food store

    66.    Light and ventilation

    67.    Bathroom and sanitary facilities

    68.    Sanitary facilities for building other than dwelling

PART VIII
Soil and Waste Drainage and Sanitary Appliances

    69.    Provision of sanitary conveniences in buildings

    70.    Drainage system of buildings

    71.    Construction of sewers

    72.    Additional requirements for sewers in or under a building

    73.    Sewer trenches near or under walls

    74.    Junctions and manholes

    75.    Construction of manholes

    76.    Ventilation of sewers

    77.    Soil, soil-waste, waste or ventilating pipes

    78.    Additional requirements for soil, soil-waste, waste or ventilating pipes

    79.    Additional requirements for waste pipes

    80.    Sanitary appliances

PART IX
Electrical Installations

    81.    Application

    82.    Conductors and apparatus

    83.    Fuses, switches and circuit-breakers

    84.    Precautions against metal becoming live

    85.    Isolation of systems and apparatus

    86.    Isolation of apparatus

    87.    Connection of appliances to supply

    88.    Precautions against special conditions

    89.    Voltages exceeding 200 volts

    90.    Electrical appliances

    91.    Light fittings, apparatus or appliances in room containing bath or shower

    92.    Wiring diagrams and distribution boards

    93.    Electric lighting

    94.    Electricity points

PART X
Scaffolds and Means of Access, Excavations and Demolition

    95.    Provision of scaffolds and means of access

    96.    Supervision

    97.    Construction, material and maintenance

    98.    Standards, uprights, ledgers and putlogs

    99.    Support and stability

    100.    Trestle scaffolds

    101.    Cantilever or jib scaffold

    102.    Working platforms and working stages

    103.    Boards and planks in working platform, gangway or run

    104.    Guard rails and toe boards at working place

    105.    Construction and use of gangway or run

    106.    Guard rails for gangway, run or stairs

    107.    Ladders

    108.    Openings in roofs, floors or walls

    109.    Roof work

    110.    Safety of excavations

    111.    Fencing of excavations, etc.

    112.    Access

    113.    Demolition of buildings and structures

PART XI
Rodent and Ant-Proofing of Buildings

    114.    Rodent-proofing of commercial buildings

    115.    Ant-proofing of buildings

PART XII
Heat-Producing Appliances Using Bottled Gas Fuel

    116.    Gas…